Why are some parts of the genome hard to sequence?
Repeats, duplicated genes, unusual GC content and gaps in the old reference make some regions hard to read and place. Here is why, and how longer reads and the T2T reference help.
4 min read
We respect your privacy
Analytics cookies show us how the site is used; advertising cookies from Google and Meta measure our ads. Choose which to allow, and change it any time under Your Privacy Choices.
Sequencing technologies
Why DNA can be read in several ways, how Sanger, Illumina, Ion Torrent, PacBio and Oxford Nanopore each work, and how laboratories choose and combine them.
Reviewed by Matthew Brown on 24 November 2026 · 4 min read
Reading DNA has been done in several different ways, because no single method is best at everything. Some read short pieces with very high accuracy, some read very long pieces, and each trades off cost, speed, accuracy and the kinds of DNA it handles well. This article compares the main technologies in plain terms.
Reading a genome means turning chemistry into letters, and there are several ways to do that. The differences that matter most are read length (how many letters are read in one piece), accuracy per letter, how much DNA can be read per run, and what the instrument costs to run. A method that reads short fragments cheaply suits some jobs; one that reads very long fragments suits others. See What is next-generation sequencing? for the general principle of reading many fragments in parallel.
Sanger sequencing, developed in the 1970s, copies a single stretch of DNA while mixing in modified bases that stop the copying at random points. This produces fragments of every possible length, each ending in a known letter. They are sorted by size in a thin capillary tube, and a detector reads the coloured label at the end of each one, giving the sequence in order.
A reaction typically reads up to around a thousand letters from one fragment and is very accurate. It cannot be run in parallel at genome scale, but it remains a standard way to confirm a specific result found by another method.
Illumina instruments, the most widely used for whole genomes, copy DNA fragments into clusters on a glass surface and build a new strand one letter at a time. Each base carries a fluorescent label and a chemical block (a reversible terminator) so only one letter is added per cycle; a camera records the colour, the block is removed, and the cycle repeats. Reads are short, typically 100 to 300 letters, and are usually read from both ends of a fragment. The full process is described in What is next-generation sequencing?.

Ion Torrent sequencing uses no light or camera. When a base is added to a growing strand, a hydrogen ion is released, and a tiny sensor in a semiconductor chip detects the resulting change in pH. The instrument flows one type of base at a time and records whether, and how strongly, the pH changes.
A known weakness is homopolymers, runs of the same letter such as AAAAAA. The signal grows with the length of the run, so telling six letters from seven is harder than telling apart different bases. Reads are usually a few hundred letters long, and the platform is often used for small, targeted tests.
PacBio sequencing watches a single DNA polymerase copy a single DNA molecule. The enzyme sits at the bottom of a nanometre-scale well called a zero-mode waveguide, so the detector sees only the fluorescent flash from the base being added at that moment. Raw single passes are long but error-prone.
For HiFi reads, the molecule is made circular and read around the loop many times. Combining those passes into a circular consensus corrects the random errors, giving reads typically 10,000 to 25,000 letters long with accuracy typically above 99.9%.


Nanopore sequencing threads a DNA strand through a tiny protein pore set in a membrane, while an electrical current flows across it. Each short stretch of bases in the pore changes the current in a characteristic way, and software translates the current signal into letters.
Because the strand is read as it passes through, read length is set mainly by how long the DNA molecules are. Reads can typically run from a few thousand to hundreds of thousands of letters. Devices range from small portable ones to large benchtop instruments. The pore can also detect chemical marks on DNA, called methylation, and can read RNA directly without first converting it to DNA.
Chain termination, read by capillary electrophoresis
Sequencing by synthesis with reversible terminators
Semiconductor chip detecting hydrogen ions released as bases are added
Single-molecule real-time sequencing in zero-mode waveguides
Changes in electrical current as DNA passes through a protein pore
All figures are typical and change as chemistries improve.
| Technology | How it reads DNA | Typical read length | Typical accuracy | Good at |
|---|---|---|---|---|
| Sanger | Chain termination, capillary electrophoresis | Up to about 1,000 letters | Very high | Confirming single variants |
| Illumina | Fluorescent reversible terminators | About 100 to 300 letters | Very high per letter (above 99.9%) | Whole genomes and exomes at scale |
| Ion Torrent | pH change from released hydrogen ions | Up to a few hundred letters | High, lower in homopolymer runs | Small targeted tests |
| PacBio HiFi | Fluorescence in zero-mode waveguides, circular consensus | About 10,000 to 25,000 letters | Above 99.9% | Structural variants, repeats, phasing |
| Oxford Nanopore | Current through a protein pore | Thousands to hundreds of thousands of letters | Around 99% or higher with recent chemistry | Very long reads, portability |
The field keeps moving. Element Biosciences, Ultima Genomics and MGI/Complete Genomics (DNBSEQ) also make sequencers that read short fragments with their own chemistries, and other approaches continue to appear. Specifications change quickly, so it is best to check the maker's current documentation.
The choice depends on the question. Short reads are a good fit for reading an entire genome accurately and for finding single-letter changes. Long reads are better at spanning repeats and finding large rearrangements. Sanger is used for confirming a specific variant, and some laboratories combine two technologies so each covers the other's weak spots.
One kit, sent to your home. Your entire genome sequenced at the clinical standard used for diagnostic decisions. Physician-ready reports delivered to your Genome Manager in 6–8 weeks — permanent and updated as science advances.
Free shipping · Results in 6–8 weeks